Endoscopic diagnosis and treatment of persistent halitosis after pharyngeal flap surgery.

Finkelstein, Y; Talmi, Y P; Zohar, Y; Ophir, D · Plast Reconstr Surg · 1993

case_report · Level V

Where this comes from

Abstract

A patient presenting with persistent dramatically offensive fetid malodor 1 year after pharyngeal flap surgery is described. Nasendoscopic examination revealed the presence of a foreign body within the nasopharynx lying on the flap. The foreign body was immediately removed by endoscopic telebiopter and revealed itself to be a gauze pad forgotten during the pharyngeal flap surgery. Modern endoscopic equipment allowed both quick diagnosis of this very rare complication and immediate and simple treatment under topical anesthesia.