We have compared changes in vocal function produced after insertion of a laryngeal mask airway (LMA) with those produced by tracheal intubation in 20 patients. Using acoustic waveform analysis, we computed amplitude variability (AV), pitch variability (PV), harmonics-to-noise ratio (HNR) and additive noise level (ANL) before anaesthesia and at 1, 4, and 24 h after tracheal extubation. There were no significant changes in vocal function after extubation except for HNR ratio (P = 0.046) at 4 h in the LMA group. There were differences in all four variables at 1 h, 4 h, or both, after tracheal extubation compared with baseline in the tracheal tube group. In both groups, all variables were the same as baseline values 24 h after extubation. We observed significant differences in AV (4 h), PV and ANL (1, 4 h) values between the two groups. These observations suggest that the LMA causes less vocal change than tracheal intubation.