Three-field isocentric breast irradiation using asymmetric jaws and a tilt board.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 8256000.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Perfect abutment of medial and lateral tangential breast portals with the adjacent supraclavicular field may be achieved with ease. A simple and safe approach was developed using a tilt board and new technology that is standard on a popular linear accelerator. The patient is secured on a tilt board as a means to level the chest wall. Isocenter is placed at depth on the matchline, where asymmetric jaws are used to produce non-divergent field edges and a perfect abutment. This is done without the need for table or collimator rotations, beam-splitters, or vertical cephalad blocks. The dorsal beam edge of the tangents is made coplanar by rotating the gantry more than 180 degrees. This procedure produces a dosimetrically sharp field edge and eliminates concern about block transmission and excess dose to the contralateral breast. Set-up is fast, and the steps involved are simple and few. Advantages and limitations of this technique are presented.
Medical subject headings
- Breast Neoplasms