An image processing scheme to quantitatively extract and validate hyoid bone motion based on real-time ultrasound recordings of swallowing.
other
Where this comes from
- Record sourced from PubMed, PMID 8258453.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An image processing technique with associated hardware was developed to quantitatively extract hyoid bone motion from realtime submandibular ultrasound images recorded during the swallowing act. Videofluorographic imaging, the "gold standard" of swallowing studies, was recorded simultaneously and synchronized to the ultrasound. Hyoid position obtained from the ultrasound was validated based on the videofluorography using personal computer-based image processing methods.
Medical subject headings
- Deglutition
- Hyoid Bone
- Image Processing, Computer-Assisted