Transoesophageal echocardiographic assessment of haemodynamic function during laparoscopic cholecystectomy.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8329253.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We have measured cardiovascular changes associated with insufflation of carbon dioxide and the reverse Trendelenburg position during laparoscopic cholecystectomy, using transoesophageal echocardiography in 13 healthy patients. End-tidal carbon dioxide values increased after insufflation of carbon dioxide, with values significantly (P < 0.05) increased after lateral tilt positioning. Creation of a pneumoperitoneum was associated with increases (P < 0.05) in left ventricular end-systolic wall stress, concomitant with increases (P < 0.01) in peak airway pressure and systemic arterial pressure. In addition, left ventricular end-diastolic area decreased (P < 0.05) after reverse Trendelenburg positioning. Left ventricular ejection fraction was maintained throughout the study.
Medical subject headings
- Cholecystectomy, Laparoscopic
- Echocardiography
- Ventricular Function, Left