Evaluation of pressure changes in feeding arteries during embolization of intracerebral arteriovenous malformations.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8360735.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The pressure in 47 arteries feeding 21 arteriovenous malformations (AVM's) was investigated during transarterial embolization using a Tracker-18 microcatheter. On average, systolic pressure increased by 22 mm Hg. In AVM's with single or few feeders, embolization was usually achieved well; in contrast, giant AVM's with multiple feeders and a large arteriovenous shunt were poorly embolized. However, large AVM's with well-demarcated components may be reduced by embolization to an appropriate size for surgery or stereotactic radiation therapy. It was found that the feeding artery pressure increased significantly more in well-embolized than in poorly embolized cases. Measurements of the feeding artery pressure clarified the hemodynamics of AVM's and facilitated more successful embolization.
Medical subject headings
- Blood Pressure
- Cerebral Arteries
- Embolization, Therapeutic
- Intracranial Arteriovenous Malformations