Cytodiagnosis of breast disease using a liquid suspension medium.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 8369919.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Fine-needle aspiration cytology specimens from 187 breast lesions were processed using conventional slide cytology. Results were compared with those from 201 lesions prepared using a liquid suspension medium (Cytospin) for specimen collection, to assess the clinical utility of each technique. The frequency of diagnostic groups was similar for each method. No significant difference was found in sensitivity (conventional slide cytology 86 per cent versus Cytospin 82 per cent), specificity (72 versus 82 per cent) or diagnostic accuracy (88 versus 91 per cent). The Cytospin technique compares favourably with conventional slide cytology and can be recommended for ease of use in breast cytodiagnosis.
Medical subject headings
- Breast
- Breast Neoplasms