Revision total hip arthroplasty. Long-term results without cement.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8414429.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors present their results for cementless femoral revision arthroplasty using extensively porous coated implants. Patients have been prospectively followed for 5 to 11 years (mean 7.4 years). The revision rate was 5.7%, and the radiographic loosening rate was 1.1%, to give a mechanical failure rate of only 6.9%. As a result of the revision procedure, the pain level was improved for 89.1% of the patients, walking status was improved for 82.8% of the patients, and functional level was improved for 88.5% of the patients. These results compare very favorably with any reports on revision arthroplasty using cement with a similar length follow-up.
Medical subject headings
- Femur
- Hip Prosthesis
Anatomy
- femur
- hip