Use of expanded polytetrafluoroethylene pericardial substitute with ventricular assist devices.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8417675.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Expanded polytetrafluoroethylene membrane was used to reconstruct the pericardium after ventricular assist device insertion in 7 consecutive patients. One patient remains on support with the membrane in place and 6 have had the membrane removed. The expanded polytetrafluoroethylene membrane protected the device cannulas during repeat sternotomy and expedited the dissection of the heart and great vessels at the time of device removal. Reconstruction of the pericardium with expanded polytetrafluoroethylene membrane is recommended at the time of ventricular assist device insertion.