Evaluation of the DCL Syphilis-G enzyme immunoassay test kit for the serologic diagnosis of syphilis.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8447290.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sera have been submitted to the authors' laboratory for syphilis testing at a dramatically increased rate since the start of the human immunodeficiency virus type 1 epidemic. Thus they were interested in evaluating a new enzyme immunoassay, the DCL Syphilis-G test kit (DCL-G, Diagnostic Chemicals Ltd., Oxford, CT) for detection of immunoglobulin G antibodies to Treponema pallidum. The enzyme immunoassay format, with its potential for automation, is ideally suited for large volume batch testing. Five hundred eighty-five sera collected primarily from pediatric patients were subjected to rapid plasma reagin and DCL-G testing. The patients ranged in age from 1 day to 45 years (mean, 14.4 years). Sera yielding positive or equivocal results in duplicate by either method were tested further for T. pallidum immunoglobulin G and M antibodies by the fluorescent treponemal antibody absorbed test and the DCL Syphilis-M test kit. The sensitivity and specificity of DCL-G, considering the combined rapid plasma reagin and fluorescent treponemal antibody absorbed results as the reference, were 100% and 99.8%, respectively. It was concluded that the DCL-G assay was a simple, efficient, and accurate method for obtaining confirmed serologic evidence of past or present syphilis.
Medical subject headings
- Syphilis Serodiagnosis