Screening for osteoporosis: comparison between dual energy X-ray absorptiometry and broadband ultrasound attenuation in 1000 perimenopausal women.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 8453190.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This paper compares dual-energy X-ray absorptiometry (DXA) of the spine and hip and broadband ultrasound attenuation (BUA) of the os calcis in 1000 perimenopausal women aged between 45 and 49 years who attended a randomized Osteoporosis Screening Programme. Significant correlations were found between all DXA results and BUA, with the trochanter giving the best numerical correlation with BUA (r = 0.354, p < 0.0001). BUA was not successful in predicting women with low DXA measurements, with only 44.0% of the women whose spinal DXA falls within the lowest quartile being in the lowest quartile of BUA. Although BUA is a poor predictor of spinal and hip bone mineral density it may provide additional structural information important in fracture prediction.
Medical subject headings
- Absorptiometry, Photon
- Mass Screening
- Osteoporosis, Postmenopausal
- Ultrasonography