Long-term evaluation of hip arthroplasty in patients with an ipsilateral knee arthrodesis.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8472409.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Hip arthroplasty with an ipsilateral knee arthrodesis occurs infrequently but does raise concern regarding surgical technical difficulties, dislocation, sepsis, and long-term loosening. Sixteen patients were evaluated 7.5 years (average period) after surgery. Technical difficulties were not prohibitive. No dislocation or revision was necessary in any of the cases. Two patients died as a result of unrelated sepsis from an infected knee. Loosening and protrusio of the acetabulum occurred in two patients. Hip arthroplasty in patients with a fused knee does not incur undue risk of loosening or instability and can provide long-term good function and pain relief. Patients with multiple joint arthroplasties, in whom concurrent sepsis occurs, can have devastating results.
Medical subject headings
- Arthrodesis
- Hip Prosthesis
- Knee Joint
Anatomy
- hip
- knee