Clinical and serologic evaluation of neonates for congenital syphilis: a continuing diagnostic dilemma.

Stoll, B J; Lee, F K; Larsen, S; Hale, E; Schwartz, D; Rice, R J; Ashby, R; Holmes, R et al. · J Infect Dis · 1993

cross_sectional · Level IV

Where this comes from

Abstract

Neonates born to women with reactive serologic tests for syphilis were studied; the total of 116 included 18 who were symptomatic, 60 asymptomatic but possibly infected, and 38 asymptomatic and probably uninfected. The fluorescent treponemal antibody-absorption (FTA-ABS) 19S IgM test and an IgM capture ELISA for Treponema pallidum, both treponema-specific assays, and the reverse enzyme-linked immunospot (RELISPOT), which detects immunoglobulin-secreting cells and is a nonspecific indicator of infection, were evaluated. Sensitivities among symptomatic neonates were 88% (IgM ELISA), 73% (FTA-ABS), and 78% (RELISPOT). Specificities ranged from 97% to 100%. A major problem has been the inability to identify which asymptomatic but possibly infected neonate is really uninfected. Among 41 such babies who had all three tests done, 93% were negative by all assays, suggesting they were uninfected or recently infected. Strategies to accurately identify the truly uninfected asymptomatic newborn would prevent the unnecessary hospitalization of all at-risk infants, resulting in improved quality of care and reduced costs.