Successful transplantation of marginally acceptable thoracic organs.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8489314.
- Also identified by PMC identifier 1242835.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study evaluates the efficacy of personally inspecting marginal thoracic organ donors to expand the donor pool. The present donor criteria for heart and lung transplantation are very strict and result in exclusion of many potential thoracic organ donors. Due to a limited donor pool, 20-30% of patients die waiting for transplantation. The authors have performed a prospective study of personally inspecting marginal donor organs that previously would have been rejected by standard donor criteria. Fourteen marginal hearts and eleven marginal lungs were inspected. All 14 marginal hearts and 10 of the marginal lungs were transplanted. All cardiac transplant patients did well. The mean ejection fraction of the donor hearts preoperatively was 39 +/- 11% (range 15-50%). Postoperatively, the ejection fraction of the donor hearts improved significantly to 55 +/- 3% (p < 0.002). Nine of the ten lung transplant patients did well and were operative survivors. Our donor pool expanded by 36% over the study period. The present donor criteria for heart and lung transplantation are too strict. Personal inspection of marginal thoracic donor organs will help to maximize donor utilization.
Medical subject headings
- Heart Transplantation
- Lung Transplantation
- Tissue Donors