Malignant tracheobronchial obstructive lesions: treatment with Gianturco expandable metallic stents.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8511298.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Gianturco expandable metallic stents were placed in 14 patients with 19 malignant lesions who had tracheobronchial stenosis and/or obstruction together with dyspnea. In all 14 patients, stenotic and/or obstructive changes disappeared immediately after the procedure, and the dyspnea improved. Lumina at the sites of tracheal lesions expanded from a mean of 3.9 mm in diameter before stent placement to a mean of 13.9 mm after stent placement. Lumina at the sites of bronchial lesions expanded from a mean of 2.1 mm to a mean of 10.3 mm. Lumina at the sites of lesions caused by extrinsic compression expanded to a mean of 89.7% of normal, while lumina at the sites of lesions caused by intraluminal tumor growth expanded to a mean of 63.2% of normal. There was improvement of at least one grade of the Hugh-Jones classification in 12 patients. Ten of the patients died; in two of these patients, restenosis developed.
Medical subject headings
- Airway Obstruction
- Bronchial Diseases
- Stents
- Tracheal Stenosis