Mitral valve operation via an extended transseptal approach.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8512390.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The extended transseptal approach to the mitral valve has been used for 71 consecutive procedures. Four patients died; none had complications directly attributable to the exposure. Twenty underwent a primary reparative procedure; 30, a primary replacement procedure; and 21, a repeat procedure. Despite division of the sinus node artery, 26 of 32 patients with sinus rhythm preoperatively had sinus rhythm postoperatively; 4 had atrial fibrillation postoperatively. Twenty-seven of 37 patients with atrial fibrillation preoperatively had atrial fibrillation postoperatively; 8 had sinus rhythm postoperatively. Because the exposure provided by this extended transseptal approach is superior to that of standard approaches, we now use it routinely for mitral valve operations.
Medical subject headings
- Heart Valve Prosthesis
- Mitral Valve