Proximal interphalangeal joint arthrodesis using powered staple fixation. Observations on autopsy specimens.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 8519107.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A new method for internal fixation using power-driven staples was recently developed. In theory, this new technique should be ideal in performing small joint arthrodesis. In autopsy specimens, the biomechanical properties were observed in simulated proximal interphalangeal joint arthrodesis (PIP). The tension-band technique, acting as a control, was significantly superior. The two techniques had similar biomechanical properties. The three 7- x 7-mm staples is recommended. The tension-band technique remains the technique of choice in small joint arthrodesis.
Medical subject headings
- Arthrodesis
- Finger Joint
- Surgical Staplers
Anatomy
- hand