Effect of formaldehyde fixation on some mechanical properties of bovine bone.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 8589198.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The risk of infection of investigators working on the biomechanics of human bone from a variety of modern pathogens including the human immunodeficiency virus or the hepatitis B virus has increased recently. New safety procedures are needed to reduce that risk. The procedure we follow in our laboratory employs brief (< 3 h) fixation in formaldehyde, and we report here the effects it has on some mechanical properties of bovine bone. Results in quasistatic loading tests were almost unaffected by our fixation protocol, but a significant decrease in impact strength was found. These results indicate that there may be some interaction between fixation and strain rate dependent effects and, therefore, some caution is needed when using common biomechanical measurement methods on fixed bone material.
Medical subject headings
- Bone and Bones
- Fixatives
- Formaldehyde