Intrauterine ultrasonographic assessments of embryonic development.

Fujiwaki, R; Hata, T; Hata, K; Kitao, M · Am J Obstet Gynecol · 1995

case_series · Level IV

Where this comes from

Abstract

Our purpose was to describe embryonal anatomic structures by use of intrauterine ultrasonography with a 20 MHz flexible catheter-based, high-resolution, real-time miniature transducer. Thirty-four women about to undergo therapeutic abortion from 7 to 9.9 weeks' gestation were studied with specially developed catheter-based, high-resolution, real-time miniature (2.4 mm outer diameter) ultrasonography transducer (20 MHz). A percentage of anatomic structures visualized at each gestational age is presented. The number and the clarity of structures increased from 7 to 8 weeks of gestation; however, the image quality was degraded because of the increasing fetal size at 9 weeks. At 8 weeks secondary brain vesicles, spine, midgut herniation, liver, upper and lower limb buds, and sacral tail were visualized in all fetuses. The four-chamber view was first identified at 8 weeks, as were fingers or toes. The stomach was first noted at 9 weeks. The umbilical cord cyst was visualized in 8% of embryos at 7 weeks' gestation and in 29% of embryos at 8 weeks. One cystic hygroma was diagnosed at 8 weeks 5 days. Intrauterine ultrasonography provides information on the visualization of anatomic structures of the embryo. In this limited series one embryonic malformation was demonstrated, and thus there is a potential for its use in the detection of malformations. These results suggest that intrauterine ultrasonography has the potential to be a supplement to transvaginal ultrasonography during the first trimester in high-risk pregnancies.

Medical subject headings