Auto-positive end-expiratory pressure during one-lung ventilation using a double-lumen endobronchial tube.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8610857.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The present study was undertaken to investigate the possible relationships between the magnitude of autopositive end-expiratory pressure (auto-PEEP) and measured PaO2 during one-lung ventilation (OLV). Forty-one adults received OLV anesthesia using a tidal volume of 8 mL/kg and a respiratory rate of 12 breaths/min. Auto-PEEP was quantified using an end-expiratory port occlusion method. During two-lung ventilation (2LV), auto-PEEP was observed in 18 of 41 patients and ranged from 0.5 to 2.5 cm H2O. During OLV, auto-PEEP was observed in 34 of 41 patients and ranged from 0.5 to 10 cm H2O. The mean (+/- SD) value of auto-PEEP was significantly higher during OLV than during 2LV (3.2 +/- 3.3 cm H2O versus 0.5 +/- 0.7 cm H2O, P < 0.0001). Auto-PEEP during OLV correlated inversely with preoperative forced expiratory volume in 1 s/forced vital capacity (y = 12.5 - 0.13x, r = -.05, P < 0.005). During OLV, there was no significant correlation between auto-PEEP and measured PaO2. These findings confirm that many patients do not exhale completely to functional residual capacity during OLV.
Medical subject headings
- Intubation, Intratracheal
- Lung
- Positive-Pressure Respiration