Dissection of an allograft ascending aorta after aortic root replacement.

Smith, J A; McKenzie, T C; Davis, B B · Ann Thorac Surg · 1996

case_report · Level V

Where this comes from

Abstract

THe case of a 57-year-old man with dissection of an allograft ascending aorta 2 months after aortic root replacement is presented. Most likely traumatic in origin, this unusual complication was managed by Dacron graft replacement of the ascending aorta using hypothermia and circulatory arrest.