Gantry angulation in CT-guided percutaneous adrenal biopsy.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8623623.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study was performed to test a new method for CT-guided adrenal biopsy using angulation of the CT gantry. In 23 patients, 26 biopsies were performed on patients in the prone position using CT gantry angulation and the introduction of the biopsy needles along the same angle, guided by the gantry locating light. The use of angulation ensured a safe needle path that avoided vital structures, such as the pleura, while monitoring of the needle course and its tip on one or two CT slices. Twenty-two of 23 adrenal masses (96%) were successfully biopsied without complications. Fifteen (65%) of the target masses were 1.5 cm or smaller. Using an angled gantry during percutaneous biopsy is a safe and preferred method over other techniques for biopsy of adrenal masses and can be used easily for small adrenal masses.
Medical subject headings
- Adrenal Glands
- Biopsy, Needle
- Radiography, Interventional
- Tomography, X-Ray Computed