Characteristics of an in vivo canine model of phonation with a constant air pressure source.

Nasri, S; Namazie, A; Ye, M; Kreiman, J; Gerratt, B R; Berke, G S · Laryngoscope · 1996

basic_science · Level V

Where this comes from

Abstract

Many previous studies of laryngeal biomechanics using in vivo models have employed a constant air How source. Several authors have recently suggested that the lung-thorax system functions as a constant pressure source during phonation. This study describes an in vivo canine system designed to maintain a constant peak subglottic pressure (Psub) using a pressure-controlling mechanism. Increasing levels of recurrent laryngeal nerve (RLN) stimulation resulted in a significant rise in resistance followed by a plateau. For a given Psub, flow decreased significantly and precipitously with increasing stimulation and then quickly plateaued. Vocal intensity increased with increasing RLN stimulation until a peak was reached. After this peak, intensity dropped until a plateau was reached, corresponding to the flow minimum. At a given Psub, increasing levels of RLN stimulation resulted in a normal distribution of vocal efficiencies.