Radiation-attenuating surgical gloves: effects of scatter and secondary electron production.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 8657942.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the effects of scatter and secondary electron production on the protection provided by flexible radiation-attenuating gloves. Four sets of radiation-attenuating flexible gloves and one set of standard surgical gloves were tested for scattering characteristics and secondary electron production caused by the interactions of x rays inside the gloves. A thin-window ion chamber was used to measure the penetration of secondary electrons in polyethylene. A diagnostic-type chamber was used to measure forward-scattered and backscattered x rays produced by the gloves. Forward-scattered and backscattered x rays added an average of about 13% to the exposure of the hands. Secondary electrons increased the signal in the thin-window chamber by large factors but were weakly penetrating, and only a small fraction produced by x rays of 90 kVp and higher energies contributed to dose to basal cells. Forward-scattered and backscattered x rays reduce the effectiveness of radiation-attenuating gloves, and secondary electron dose to basal cells in the back of the hand can further reduce effectiveness.
Medical subject headings
- Gloves, Protective
- Radiation Protection
- Radiology