Inadvertent extradural insertion of an internal jugular catheter in an infant.

Skinner, T A; Mather, S J · Br J Anaesth · 1995

case_report · Level V

Where this comes from

Abstract

We present an unusual complication of left internal jugular vein catheterization in an 11-week-old infant which we believe has not been described previously. After failed subclavian catheterization, a left internal jugular catheter was placed without apparent difficulty. Confirmatory chest x-ray revealed that the tip of the catheter was in the extradural space.