Analysis of ethanol in expired air during low-flow isoflurane anaesthesia.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 8672387.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Monitoring of ethanol concentration in expired air is a method for assessing fluid absorption during transurethral prostatic surgery and endometrial resection, but the validity of this technique has not been studied in low-flow ventilation systems. For this purpose, we have compared the concentration-time profiles of ethanol in expired gas and in venous blood during an i.v. infusion of 0.4 g kg-1 of ethanol over 30 min in 10 women during isoflurane anaesthesia and in the awake state. Anaesthesia increased the ethanol concentration in expired gas by 13% and in venous blood by 34%. The expired gas-blood difference during infusion was abolished, and the central volume of distribution for ethanol was reduced from 20.9 to 8.6 litre, on average. We conclude that breath sampling during low-flow isoflurane anaesthesia reflects an alcohol load well, but that a change in ethanol disposition makes the values slightly higher than in the awake state.