Albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 8706467.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To assess albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model and to determine the influence of the following variables on albuterol delivery: endotracheal tube diameter; type of spacer; humidification; and pulmonary mechanics. Prospective, in vitro, laboratory study. Research laboratory. A model, consisting of a volume-cycled ventilator, pediatric breathing circuit, 4.0- or 6.0-mm endotracheal tube, and lung simulator, was assembled. Ventilator settings were: tidal volume 250 mL; FIO2 0.5; inspiration/expiration ratio 1:3; respiratory rate 25 breaths/min; positive end-expiratory pressure 3 cm H2O; temperature 35 degrees C; and a decelerating flow pattern, using dry and humidified air. Lung simulator compliance and resistance values were consistent with those values reported for healthy childeren (20 mL/cm H2O and 40 cm H20/L/sec) and children with pulmonary disease (10 mL/cm H2O and 60 cm H2O/L/sec). Pulmonary mechanics were verified with a pulmonary function diagnostic system. Ten metered-dose inhaler canisters were used to administer 2000 micrograms of albuterol, using either a collapsible or a rigid spacer. A circuit filter placed immediately proximal to the test lung collected drug exiting the endotracheal tube. The filter was rinsed with water and albuterol concentrations were determined by high-performance liquid chromatography. Each variable was tested in triplicate. Albuterol delivery was significantly (p < or = .05) greater for the 6.0-mm endotracheal tube, rigid spacer, dry air, and pulmonary disease mechanics by multifactor analysis of variance. Drug delivery in humidified air with pulmonary disease mechanics using the rigid chamber was 2.5 =/- 0.27% and 6.3 =/- 0.99% for the 4.0- and 6.0-mm endotracheal tubes, respectively. These in vitro results suggest that pulmonary disease mechanics and a 6.0-mm endotracheal tube improve albuterol delivery. Future clinical investigations in intubated pediatric patients with pulmonary disease are needed to address the clinical significance of these results.
Medical subject headings
- Albuterol
- Asthma
- Bronchodilator Agents
- Drug Delivery Systems
- Nebulizers and Vaporizers
- Respiration, Artificial