Exercise tolerance in patients with mitral stenosis before and after acute percutaneous mitral valvuloplasty. Role of lung diffusing capacity limitation?
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8733094.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to specify in patients with tight mitral stenosis whether lung diffusing capacity could play a role in their exercise intolerance. A similar study was recently carried out in patients with moderate chronic heart failure. Ten patients with tight mitral stenosis were studied before and 6 months after successful percutaneous transvenous balloon valvuloplasty and compared to six control subjects. Measurements of diffusing capacity, evaluated by the lung transfer factor (TLCO) and by the transfer coefficient (TLCO/VA), obtained at rest and during early recovery after cardiopulmonary exercise testing were performed. Cardiac output was determined non-invasively, both at rest and during exercise, using the carbon dioxide exponential rebreathing technique. Prior to valvuloplasty, TLCO and TLCO/VA were not different at rest between the two groups. During exercise, patients differed from control subjects, with lower oxygen uptake (P < 0.001) and lower cardiac output at peak exercise (P < 0.001). These values at peak exercise were significantly correlated (P = 0.02; r = 0.75). Moreover, patients differed from control subjects at early recovery after peak exercise with an absence of increase in TLCO (P < 0.05). Six months after valvuloplasty, a decrease of both TLCO (P < 0.01) and TLCO/VA (P < 0.05) was observed at rest. During exercise, comparison of patients demonstrated a significant increase of both peak exercise oxygen uptake (SLVO2, P < 0.01) and cardiac output (P < 0.001). At early recovery after peak exercise there was a significant increase in TLCO (P < 0.05) and TLCO/VA (P < 0.01), such that a delta TLCO and a delta TLCO/VA appeared (P < 0.05) identical to that observed in control subjects. Moreover, delta SLVO2 was significantly correlated in patients with delta Q+ delta TLCO/VA (P = 0.02; r = 0.72). In conclusion, this study suggests a role, at least partial, of lung diffusing capacity in exercise intolerance in patients with tight mitral stenosis and in the improvement of their aerobic exercise capacity demonstrated after successful percutaneous balloon valvuloplasty.
Medical subject headings
- Angioplasty, Balloon, Coronary
- Exercise Tolerance
- Mitral Valve Stenosis
- Pulmonary Diffusing Capacity