Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screw.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8736292.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The results of internal fixation of 55 subcapital fractures of the femoral neck with a one-hole plate dynamic hip screw are presented. Two fractures could not be satisfactorily fixed and the procedures were converted to hemi-arthroplasties, but the remainder united within 6 months. The rate of avascular necrosis after union was 3 per cent in undisplaced and 31 per cent in displaced fractures. This method of fixation appears to produce a lower non-union rate than multiple pins in suitable fractures without affecting the incidence of late avascular necrosis.
Medical subject headings
- Bone Plates
- Bone Screws
- Femoral Neck Fractures
- Femur Neck
- Fracture Fixation, Internal