Aortic valve replacement with a pulmonary autograft in infants with critical aortic stenosis.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8751512.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Seven patients with critical aortic stenosis underwent aortic valve replacement with a pulmonary autograft (the Ross operation) between the ages of 5 weeks and 9 months. The operation was considered mandatory for survival because of continued severe heart failure or valve avulsion. Six of the patients had undergone unsuccessful previous palliations, such as commissurotomy, balloon dilation, and transventricular valvotomy, performed singly (n = 1) or in combination (n = 5). The other patient with a severely hypoplastic aortic valve ring underwent the Ross procedure as a primary operation. Two operative deaths occurred. In both cases severe endocardial fibroelastosis was detected at autopsy. One late death 1 year after the operation resulted from progressive hypertrophic cardiomyopathy and pulmonary hypertension. The rest of the patients are doing well, without medications. Apart from trivial regurgitation in two patients, the pulmonary autograft is performing well.
Medical subject headings
- Aortic Valve
- Aortic Valve Stenosis
- Pulmonary Valve