Adrenal masses: correlation between CT attenuation value and chemical shift ratio at MR imaging with in-phase and opposed-phase sequences.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 8756926.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To correlate attenuation values at computed tomography (CT) with signal intensity at chemical-shift magnetic resonance (MR) imaging in adrenal masses. Thirty-eight patients with 47 adrenal lesions underwent MR imaging and unenhanced CT examinations. MR examinations, performed at 1.5 T, included T1-weighted imaging with fat and water in phase and gradient-echo imaging with fat and water out of phase (repetition time, 45-180 msec; echo time, 1.4-3.1 msec). Lesion-to-spleen signal intensity ratios were calculated for the in-phase and opposed-phase images. The chemical-shift ratio, a measure of signal intensity loss between in-phase and opposed-phase images, and the CT attenuation value (in Hounsfield units) were determined for each lesion. A statistically significant correlation (0.85) was found between attenuation and chemical-shift-ratio values (P < .000001). Attenuation in six benign lesions was within 2 standard deviations of the mean attenuation in malignant lesions, and the chemical-shift ratio in eight benign lesions was within 2 standard deviations of the mean chemical-shift ratio in malignant lesions. Six of these eight lesions were misclassified on the basis of both attenuation and chemical-shift-ratio values. CT attenuation values are highly correlated with chemical-shift ratios. Both values were indeterminate for a similar subset of benign lesions.
Medical subject headings
- Adrenal Gland Neoplasms
- Adrenal Glands
- Tomography, X-Ray Computed