Fracture of the femoral neck: optimal screw position and bone density determined by computer tomography.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 8762791.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The bone density of five proximal femurs from female cadavers was measured with computed tomography using a pixel size of 1.2 mm. A three dimensional reconstruction was performed along four well-defined axes. The region of maximal relative bone density correlated well with a previous report of the optimal position of a screw when treating a fracture of the femoral neck.
Medical subject headings
- Bone Density
- Bone Screws