Penile vibratory stimulation in spinal cord injured men: optimized vibration parameters and prognostic factors.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 8822683.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To study the efficacy of penile vibratory stimulation (PVS) with optimized vibration parameters in spinal cord injured (SCI) men and to examine prognostic factors for success. Case series. University hospital outpatient clinic. Thirty-four consecutive SCI men seeking fertility treatment. PVS with optimized vibration parameters to induce reflex ejaculation. Ejaculatory response; semen analysis. Antegrade ejaculation was seen in 65% of patients. High rates were seen in lesions above T10 (81%) and in presence of hip flexion and bulbocavernosus reflexes (77%). Of men with lesions above T10, those with a penile prosthesis had lower ejaculation rates (40% vs 90%). Average total sperm counts were 968 million, with 26% motility. High rates of ejaculation are seen with optimized vibration parameters, especially in men with lesions above T10 and intact lower spinal reflexes. A penile prosthesis may impair success with PVS.
Medical subject headings
- Ejaculation
- Infertility, Male
- Penis
- Spinal Cord Injuries
- Vibration