The harmonic scalpel: an intraoperative complication.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 8841266.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The harmonic scalpel is an ultrasonically activated surgical instrument for tissue dissection. Despite its expanding surgical applications, there are no reports about associated complications. A 35-year-old woman sustained injury to the sigmoid colon from the use of the harmonic scalpel during laparoscopic lysis of pelvic adhesions. The injury was identified and repaired laparoscopically in a primary fashion with no subsequent sequelae. Acoustic energy coupling and overheating of the laparosonic blade extender sheath occur with bending of the instrument. This can happen with steering of the blade extender during laparoscopic surgery and may increase the exposure risk of adjacent tissues to injury.
Medical subject headings
- Colon, Sigmoid
- Laparoscopy
- Surgical Instruments
- Ultrasonics