False-positive iodine-131 whole-body scans due to cholecystitis and sebaceous cyst.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 8862313.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
False-positive whole-body 131I scans are not frequent but have serious consequences in the management of patients with thyroid cancer. They can be classified in four main groups: elimination of iodine in body fluids, infection or inflammation, cysts or transudates and nonthyroid tumors. We report on two patients with false-positive post-therapy 131I scans. The first patient had uptake projected in the right pelvic area which was later proven to be a large gluteal sebaceous cyst. The second patient had uptake in the gallbladder area that did not disappear after 131I treatment; she underwent exploratory laparotomy which revealed extensive chronic cholecystitis. These cases illustrate two new causes of false-positive 131I whole-body scans (sebaceous cyst and cholecystitis), which highlights two mechanisms (elimination in body fluid and inflammation).
Medical subject headings
- Adenocarcinoma, Follicular
- Carcinoma, Papillary
- Cholecystitis
- Epidermal Cyst
- Iodine Radioisotopes
- Thyroid Neoplasms