Compartment syndrome of the buttock following a total hip arthroplasty.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 8872583.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
An elevation of the interstitial pressure in a closed osseofascial compartment results in compartment syndrome. This may be caused by a decrease in compartment volume or an increase in compartment contents. The gluteal compartment syndrome is rare. Because the gluteal region has a large volume, this compartment requires a massive increase in content to cause a compartment syndrome. Also, this compartment blends anatomically with the muscles of the thigh, allowing extravasation of blood outside the compartmental envelope. This case report is of a patient whose medial circumflex femoral artery was severed during a total hip arthroplasty through a posterior approach leading to compartment syndrome of the buttock. Although this clinical presentation has not been described as compartment syndrome, one similar presentation was described in the literature.
Medical subject headings
- Aged
- Buttocks
- Compartment Syndromes
- Compartment Syndromes/etiology
- Female
- Hip Prosthesis
- Hip Prosthesis/adverse effects
- Humans
Anatomy
- hip