Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use.

Mallory, T H; Head, W C; Lombardi, A V; Emerson, R H; Eberle, R W; Mitchell, M B · J Arthroplasty · 1996

retrospective_cohort · Level III

Where this comes from

Abstract

Between 1984 and 1986, 177 nonconsecutive, primary total hip arthroplasties were performed in 150 patients using the Mallory-Head Porous femoral component (Biomet, Warsaw, IN) inserted without cement. Average time to follow-up evaluation for the entire population (including all early revisions) was 76 months (6.3 years). There were 10 revisions (6%) with an average time to revision of 50 months (4.2 years). Two revisions were for component undersizing; three revisions were for aseptic loosening; four revisions were for acetabular component failure and one revision was due to a femoral fracture secondary to trauma. At the most recent follow-up visit, the average Harris hip score for all hips increased from 41.5 before surgery to 86.8 (P < .001). Radiographic assessments yielded an average Engh fixation score of 20.7. The Kaplan-Meier survival estimate for the average time to follow-up evaluation was 0.98. Based on our patient selection criteria and excellent intermediate clinical and radiographic results, the initial design strategies of the Mallory-Head Porous femoral prosthesis have been confirmed.

Medical subject headings

Anatomy