Arthroscopic internal fixation of fractures of the intercondylar eminence of the tibia.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 8902138.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We treated a 53-year-old man with a fracture of intercondylar eminence of the tibia. He had a nondisplaced (type I) fracture at the first examination and was treated by long leg cast. However, 4 weeks later, it was found that the fracture was displaced, which suggests that nondisplaced fracture of intercondylar eminence may displace later. We recommend primary arthroscopic fixation for type I fractures of the intercendolar eminence of the tibia, because it is difficult to reduce the fragment arthroscopically once it is displaced. This report describes a new technique of arthroscopic reduction and internal fixation for the fractures intercondylar eminence of the tibia.
Medical subject headings
- Arthroscopy
- Endoscopy
- Fracture Fixation, Internal
- Knee Injuries
- Tibial Fractures
Anatomy
- tibia
- knee