Removal of intramedullary nails from the femur: a review of 45 cases.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 8915919.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The excellent biocompatibility of titanium and its alloys may result in osseointegration. In order to determine if this presents an obstacle to removal of intramedullary nails, we retrospectively reviewed a series of 45 cases of isolated removal of a femoral nail. Indications for removal were persistent pain and discomfort, request of an asymptomatic patient, or skeletal immaturity. Twenty-three nails were titanium, and 22 were stainless steel. Although removal of the titanium nails had a significantly longer operative time (110 vs. 84 min), analysis of variance indicated that this was due to a greater number of crosslocking screws in the titanium nails (2.2 vs. 0.6) and a tendency to set the titanium nails deeper in the femur. The use of the titanium material per se did not pose a risk factor for difficulty in late removal of an intramedullary nail.
Medical subject headings
- Bone Nails
- Femoral Fractures
Anatomy
- femur