Surgical exposure of the dorsal proximal third of the radius: how vulnerable is the posterior interosseous nerve?
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 8933455.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study determined the distance between the posterior interosseous nerve and the bicipital tuberosity of the radius in cadavers. Both elbows of 15 preserved cadavers were dissected (eight male cadavers, seven female cadavers). The most prominent point of the radial tuberosity was located, and the shortest distance from this area to the posterior interosseous nerve was measured. The average distance was 2.3 cm (range 1.8 to 3.2 cm); the intracadaver (right vs left) variation was 1.3 mm. The tuberosity to nerve distance was unaffected by forearm rotation. Palpation of the prominence of the radial tuberosity is a reliable guide to the position of the posterior interosseous nerve in dorsal approaches to the proximal forearm.
Medical subject headings
- Forearm
- Radius
Anatomy
- radius