Outcome of total hip arthroplasties with cement. Results after implantation of the Harris Design 2 prosthesis, 1983-1985.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 8934318.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Most reports of excellent long-term results of cemented total hip arthroplasty originate from studies of Charnley prostheses. A radiographic and clinical study was performed on 126 patients who underwent a cemented total hip arthroplasty from 1983 to 1985 with the Harris Design 2 prosthesis (Howmedica, Rutherford, NJ). The femoral component was cobalt-chromium and it had a broad, rounded medial border and a collar. The head diameter was 26 mm. A cemented all-polyethylene socket was used in all cases. At the last follow-up examination, 71% of the patients were completely free of pain and no patient had severe pain or pain at rest. Kaplan-Meier survival analysis estimated the revision rate at 10 years after operation to be 5 +/- 2% (mean +/- SEM) (including planned revisions). The rate of complete acetabular demarcation was 20% at 10 years, and femoral demarcation involving more than 50% of the bone-implant surface or endosteal cavitation was noted in only three cases. These results are as good as the best reported after total hip arthroplasty with the Charnley prosthesis.
Medical subject headings
- Hip Prosthesis
Anatomy
- hip