Experimental results with endovascular irradiation via a radioactive stent.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 8960505.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of this article is to describe the methods used to manufacture a radioactive stent and to review the experimental data on this therapy designed to improve arterial patency rates after stent placement. Surface activation in a cyclotron and ion implantation techniques are used to render commercially available vascular stents radioactive. beta-Particle-emitting stents, most commonly 32P, were employed because of their short half-life (14.3 days) and limited range of tissue penetration (3-4 mm). The function and vascular response to these 32P radioactive stents with varying activities (range 0.14-23 microCi) was evaluated in several animal models of arterial injury and restenosis. In porcine iliac arteries, beta-particle-emitting stents with an initial activity of 0.14 microCi reduced neointimal formation 37% at 28 days after implant. On histology, the neointima consisted of smooth muscle cells and a proteoglycan-rich matrix. Scanning electron microscopy demonstrated complete endothelialization of the stent. beta-Particle-emitting stents with an initial activity of 3-23 microCi inhibited neointimal smooth muscle cell proliferation at 28 days in a porcine coronary restenosis model. The neointima within these high-activity stents consisted of fibrin, erythrocytes, and only rare smooth muscle cells. Studies with 1-year follow-up after implantation of a radioactive stent with a composition of gamma- and beta-particle-emitting radionuclides 55,56,57Co, 52Mg, and 55Fe and an initial activity of 17.5 microCi demonstrated almost complete inhibition of neointimal proliferation in a rabbit model. Endovascular irradiation delivered via a radioactive stent reduces neointimal formation and improves luminal patency without increasing the risk for stent thrombosis in experimental models of restenosis. The optimal radiation dose is unknown. At stent activities >3 microCi of 32P, the inhibition of neointimal formation is due to direct radiation affects on proliferating smooth muscle cells. At ultra-low activities (0.14 microCi), beta-particle irradiation reduces neointimal formation possibly by impairing cell proliferation or migration. This novel therapy may have a significant impact on preventing stent restenosis, and requires further investigation.
Medical subject headings
- Brachytherapy
- Coronary Vessels
- Endothelium, Vascular
- Iliac Artery
- Muscle, Smooth, Vascular
- Stents