Prosthesis displacement as a complication of reduction of a dislocated total hip arthroplasty.

Holt, M D · J Arthroplasty · 1996

case_report · Level V

Where this comes from

Abstract

Acute displacement at the cement-prosthesis interface of the femoral component of a hip arthroplasty that occurred as a consequence of attempted reduction of a dislocation is described. Although this complication is theoretically possible with a polished tapered stem design, it is previously unrecognized, and may be avoidable if fluoroscopic control is used during closed reduction of a dislocation.

Medical subject headings

Anatomy