Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: optimization with a test examination and a power injector.

Earls, J P; Rofsky, N M; DeCorato, D R; Krinsky, G A; Weinreb, J C · Radiology · 1997

prospective_cohort · Level II

Where this comes from

Abstract

To optimize findings at dynamic gadolinium-enhanced hepatic magnetic resonance imaging in the hepatic arterial phase, a timing examination was performed after injection of a 0.5-mL timing bolus of gadopentetate dimeglumine. In the experimental group (n = 28), power injection was used and the imaging delay was determined in each patient on the basis of the results of the timing examination. In the control group (n = 28), hand injection and a fixed 20-second imaging delay were used. Arterial-phase examinations (defined as relative liver enhancement of not more than 30% of peak parenchymal enhancement) were successful in 26 (93%) experimental group patients and in 17 (61%) control group patients.

Medical subject headings