Hepatic arterial-phase dynamic gadolinium-enhanced MR imaging: optimization with a test examination and a power injector.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 8988222.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To optimize findings at dynamic gadolinium-enhanced hepatic magnetic resonance imaging in the hepatic arterial phase, a timing examination was performed after injection of a 0.5-mL timing bolus of gadopentetate dimeglumine. In the experimental group (n = 28), power injection was used and the imaging delay was determined in each patient on the basis of the results of the timing examination. In the control group (n = 28), hand injection and a fixed 20-second imaging delay were used. Arterial-phase examinations (defined as relative liver enhancement of not more than 30% of peak parenchymal enhancement) were successful in 26 (93%) experimental group patients and in 17 (61%) control group patients.
Medical subject headings
- Contrast Media
- Gadolinium
- Hepatic Artery
- Injections
- Liver
- Liver Diseases
- Magnetic Resonance Imaging
- Meglumine
- Organometallic Compounds
- Pentetic Acid