Abstract
Thirty-six healthy patients, ASA 1, aged 16-41 years, scheduled for elective plastic surgery were studied to determine if thoracocervical or lumbar epidural blocks affected the lag time of the pulse oximeter response. Patients were allocated to receive thoracocervical epidural block (n = 20) (group 1) (lignocaine 1%) or lumbar epidural block (n = 16) (group 2) (lignocaine 1.5%). Epidural block was performed with a 17-gauge Tuohy needle inserted in the midline between C7-T2 vertebrae in group 1 and between L1-S1 in group 2 and an epidural catheter was introduced. Arterial oxygen saturation (SpO2) was measured continuously using a Datex pulse oximeter. The lag time of the pulse oximeter response was measured while breathing oxygen (100%) after breath-holding. Values were obtained 10 min before and 5, 10, 15, 20, 30, and 40 min after epidural injection of a test dose. There was a progressive decrease in the lag time of the pulse oximeter response so that by 30 min after epidural injection the mean (SD) value had decreased from 29 (6.1) to 14 (3.4) in Group 1 and 41 (12.8) to 23 (7.9) s in group 2 (p < 0.01).
Medical subject headings
- Anesthesia, Epidural
- Monitoring, Intraoperative
- Oximetry