Serum glutathione S-transferase concentrations and creatinine clearance after sevoflurane anaesthesia.

Darling, J R; Murray, J M; McBride, D R; Trinick, T R; Fee, J P · Anaesthesia · 1997

rct · Level II

Where this comes from

Abstract

The effects of sevoflurane and isoflurane on serum glutathione S-transferase concentrations and creatinine clearance were compared in 50 ASA I-III patients aged over 18 years undergoing body surface surgery of 1-3 h predicted duration. Patients randomly received sevoflurane (n = 24) or isoflurane (n = 26) in nitrous oxide and oxygen (FIO2 = 0.4) via a nonrebreathing system. Fluids were standardised and patient's lungs ventilated to normocapnia. Expired concentration of anaesthetic agent was adjusted to maintain systolic arterial pressure between 70 and 100% of baseline. Patients received significantly less (p < 0.05) sevoflurane (1.0 MAC-h) than isoflurane (1.5 MAC-h). Using serum glutathione S-transferase concentrations and creatinine clearance as markers of hepatic and renal function respectively, no statistically significant differences were identified between the groups.

Medical subject headings