Comparison of p53 immunoreactivity in fresh-cut versus stored slides with and without microwave heating.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 9071730.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Because of technical problems in immunohistochemical staining of archival material, antigens can be masked or lost. A recent study reported diminished p53 immunoreactivity in slides that had been sectioned from parafinn-embedded tissue blocks and stored at room temperature. To investigate this issue, we performed immunohistochemical staining with use of a p53 monoclonal antibody (DO7) in 13 head and neck squamous cell carcinoma (HNSCC) and 13 non-small-cell lung carcinomas. The fresh-cut and stored slides were simultaneously stained with and without the use of a microwave heating (MWH) technique, and we compared the results of p53 immunostaining. The stored slides were sectioned from paraffin blocks 4 to 25 years old and kept at room temperature for 6 to 48 months. The slides were blindly evaluated for percentage of positivity and staining intensity. Twelve HNSCCs and six lung carcinomas showed p53 positivity. The stored slides showed a considerable decrease in staining intensity (P = 0.039), compared with fresh-cut slides. The difference in the percentage of positivity between the stored and fresh-cut slides was statistically significant, but the mean value of the difference was only 3.6%, which might not be meaningful for semiquantitation of immunostaining. MWH greatly enhanced staining intensity and percentage of positivity for both stored and fresh-cut slides. When MWH was applied, no significant difference in staining intensity (P = 0.063) was detected in fresh-cut versus stored slides, but the difference in the percentage of positivity was statistically significant (mean value, 3.1%). Individual cases showed a consistent p53 status regardless of the MWH treatment, storage duration, or age of the blocks. This study demonstrated a considerable decrease in p53 immunoreactivity in stored slides. Because the MWH successfully retrieved the p53 antigen without causing a change in p53 status, stored slides combined with an MWH antigen retrieval technique in a metal-containing solution should provide p53 immunostaining results similar to those from fresh-cut slides, as long as staining intensity is not a sole study parameter.
Medical subject headings
- Immunohistochemistry
- Lung Neoplasms
- Microwaves
- Tissue Preservation
- Tumor Suppressor Protein p53