Abstract
An He-Ne scanning laser beam was used to measure for the first time the linear shrinkage of light-cured microfilled composites. A low-power beam, which has a wavelength (632.8 nm) different from the polymerization wavelength (approximately 450 nm), was used. In these conditions no shrinkage is induced by the laser light. This method of measurement makes it possible to analyse small samples with a very low error (1.1 microns). Five different materials were tested using 10-20 mg specimens, and the shrinkage process was examined in detail over 2 days. All these materials showed shrinkage of more than 50% of their original length after 1 min of irradiation and approximately 99% of the total shrinkage occurred 4 h after irradiation.
Medical subject headings
- Biocompatible Materials
- Composite Resins
- Dental Materials