Trephination and suturing of avascular meniscal tears: a clinical study of the trephination procedure.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 9115563.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
On the basis of animal studies, an arthroscopic surgical system and procedure of trephination plus suturing were designed for clinical practice. The system consists of a trephine with a tooth-like tip, a guide, and an ordinary arthroscopic power handle. The guide introduces the trephine to the tear without abrading articular cartilage and controls the depth of the trephination. The power handle connected to a suction system provides an inside-out cut core of meniscal tissue. Thirty-six patients with meniscal tears underwent arthroscopic trephination plus suturing (group TS) and 28 patients had suturing alone (group S). The follow-up was 25 to 78 months. Two symptomatic retears have occurred in group TS and 7 symptomatic retears in group S. The symptomatic retear rate of group TS was significantly smaller than group S (P < .01). It is indicated that the patients treated with trephination have fewer symptoms and lower clinical failure rate. Arthroscopic trephination is a safe and easy procedure.
Medical subject headings
- Arthroscopes
- Endoscopy
- Menisci, Tibial
- Suture Techniques
Anatomy
- tibia