Combined epicardial-transthoracic electrode paddle placement: a method for defibrillation during open-chest cardiac resuscitation.

Kerber, R E; Davis, J E · Resuscitation · 1997

case_report · Level V

Where this comes from

Abstract

We present a case of open-chest cardiac massage where ventricular fibrillation developed and a direct current shock was required. In the absence of 'surgical' electrode paddles, standard paddle electrodes were used; one small electrode was placed directly on the exposed epicardial surface and the second electrode was placed on the lateral chest wall. Defibrillation was achieved with a 100 J shock. This combined epicardial-transthoracic electrode paddle placement technique allows defibrillation to be accomplished when open chest cardiac massage is being performed and no 'surgical' electrode paddles are available.